HH-00001
The Wondfo OCG-102 Optical Coagulation Analyzer is a compact and portable point-of-care coagulation testing system designed for rapid assessment of key blood coagulation parameters.
The analyzer supports PT, PT/INR, APTT, TT, FIB and ACT, making it suitable for anticoagulation monitoring and coagulation assessment in hospitals, clinics, operating theatres, intensive care units, emergency departments and other point-of-care environments.
Only 20 µL of whole blood is required for testing. Depending on the assay, the OCG-102 accepts citrated venous whole blood, while PT/INR can also be performed using capillary whole blood. Results are available in 5 minutes or less, helping clinicians obtain coagulation information without relying solely on a centralized laboratory workflow.
The OCG-102 uses disposable dry-reagent test strips that can be stored at room temperature. Wondfo's 2024 catalogue specifies 2–30°C storage and an 18-month shelf life for the test strips. The analyzer itself incorporates a rechargeable lithium battery, making it particularly useful where portability is important.
Key Features
Portable optical coagulation analyzer
Point-of-care testing platform
Tests PT PT/INR APTT TT FIB and ACT
Only 20 µL sample volume
Results within ≤5 minutes
Precision of CV ≤5%
Citrated venous whole-blood testing
Capillary whole-blood testing for PT/INR
Disposable dry-reagent test strips
One-step testing workflow
Rechargeable lithium battery
Approximately 850 g analyzer weight
Reaction temperature of 37°C ±0.5°C
Suitable for emergency and bedside applications
CE and NMPA-qualified configuration listed by Wondfo
Technical Specifications
Specification Details
Brand Wondfo
Model OCG-102
Product Type Optical Coagulation Analyzer
Application Point-of-Care Coagulation Testing
Test Parameters PT PT/INR APTT TT FIB ACT
Sample Volume 20 µL
Primary Sample Type Citrated Venous Whole Blood
Capillary Blood Supported for PT/INR
Result Time ≤5 minutes
Precision CV ≤5%
Reaction Temperature 37°C ±0.5°C
Test Format Disposable Dry-Reagent Test Strips
Power AC Adapter / Rechargeable Battery
Battery Type Rechargeable Lithium Battery
Weight Approx. 850 g
Test Strip Storage 2–30°C
Test Strip Shelf Life 18 months
Qualification CE NMPA