Sysmex CA-104 Semi-Automated Coagulation Analyzer
Unit Price · Ex-Lagos
₦8,900,000
approx. $5,816.99 at today's rate
10 units available · MOQ 1 unit · Ships in 48hrs
Buyer protected Nationwide logistics Paystack verified
Fulfilled by Store
HH-00016
The Sysmex CA-104 Semi-Automated Coagulation Analyzer is a compact laboratory system designed to simplify and standardize routine blood coagulation testing in hospitals, diagnostic centres and clinical laboratories.
The CA-104 features four optical measurement channels and uses Sysmex's turbodensitometric photo-optical measuring principle to objectively detect clot formation. Four LEDs operating at 870 nm are used for clotting assays.
The analyzer supports PT (Prothrombin Time), APTT (Activated Partial Thromboplastin Time), TT (Thrombin Time), fibrinogen and coagulation factor assays. Depending on the assay, throughput can reach approximately 60 PT tests per hour or 30 APTT tests per hour.
Its semi-automated workflow combines manual pipetting with automatic measurement start, built-in timing, temperature-controlled incubation and automatic result calculation. A built-in thermal printer provides immediate result output.
Key Features
Four-channel semi-automated coagulation analyzer
Photo-optical turbodensitometric clot detection
4 LED detection channels at 870 nm
PT, APTT, TT and fibrinogen testing
Supports selected coagulation factor assays
Up to approximately 60 PT tests/hour
Approximately 30 APTT tests/hour
Manual pipetting with automatic start
Built-in pre-incubation timer
Temperature-controlled incubation
Four reagent positions at 37°C
16 cuvette incubation positions
Up to 15 programmable assay methods
Up to 9 calibration points
Built-in thermal printer
Compact benchtop design
Low sample and reagent requirements
Detailed Technical Specifications
Specification Sysmex CA-104
Analyzer Type Semi-Automated Optical Coagulation Analyzer
Measurement Principle Turbodensitometric Photo-Optical
Detection Channels 4
Light Source LED
Wavelength 870 nm
Primary Assays PT, APTT, TT, Fibrinogen
Factor Assays Extrinsic & Intrinsic Coagulation Factors
PT Throughput Approx. 60 tests/hour
APTT Throughput Approx. 30 tests/hour
Sample Type Centrifuged Citrated Plasma
PT Sample Volume 50 µL
APTT Sample Volume 50 µL
Fibrinogen Sample Volume 100 µL*
TT Sample Volume 50–100 µL
Factor Assay Sample Volume 5 µL*
Sample/Reagent Handling Manual Pipetting
Measurement Start Auto-Start
Measurement Channels 4 with Light-Protection Caps
Reagent Positions 4
Cuvette Incubation Positions 16
Reaction Vessel Single-Use Cuvettes with Stir Bars
Programmable Methods Up to 15 Assays
Calibration Up to 9 Calibration Points
Result Units Seconds, INR, %, mg/dL
Display 2-Line LCD, 20 Characters per Line
Printer Integrated Thermal Printer
Interface RS-232C
Dimensions (W × H × D) 270 × 95 × 310 mm
Weight Approx. 2.9 kg
Operating Voltage 100–240 VAC
Operating Temperature 10–30°C
Relative Humidity <85%