NEWSKU-24-MW2C0VHJ-CK2S
14 × 17 Inch Stationary X-Ray Anti-Scatter Grid – 35 × 43 cm
Unit Price · Ex-Lagos
₦650,000
approx. $424.84 at today's rate
10 units available · MOQ 1 unit · Ships in 48hrs
× ₦650,000
Buyer protected Nationwide logistics Paystack verified
Fulfilled by Store
HH-00004
The 14 × 17 Inch Stationary X-Ray Anti-Scatter Grid is a radiographic imaging accessory designed to improve X-ray image contrast by reducing scattered radiation before it reaches the film or digital image receptor.
Constructed with precisely arranged lead strips separated by radiolucent interspacing materials, the grid allows a greater proportion of primary X-rays to reach the image receptor while absorbing much of the scattered radiation that can reduce image clarity.
Its 14 × 17-inch format is suitable for compatible general radiography systems, including applications involving chest, abdominal, pelvic and spinal imaging.
The stationary design operates without a motorised moving mechanism and can be used with appropriately matched conventional X-ray cassettes, computed radiography (CR) plates or digital radiography (DR) detectors, depending on the grid configuration.
Suitable for hospitals, diagnostic imaging centres, radiology departments and medical X-ray facilities.
Key Features & Specifications
The specifications below describe a representative 14 × 17-inch stationary anti-scatter grid. Grid ratio, frequency and focal distance must be selected for the customer's X-ray system.
Feature / Parameter Specification
Product Type Stationary X-Ray Anti-Scatter Grid
Alternative Name Radiographic Grid / X-Ray Scatter Reduction Grid
Grid Size 14 × 17 Inches
Nominal Metric Size 35 × 43 cm
Grid Movement Stationary / Fixed
Primary Function Scattered Radiation Reduction
Grid Construction Parallel Lead Strips with Radiolucent Interspaces
Absorbing Material Lead
Interspace Material Aluminium or Fibre
Grid Ratio 8:1, 10:1 or 12:1, Depending on Configuration
Example Configuration 8:1 Ratio
Grid Line Density 103 Lines/Inch (approximately 40 Lines/cm)
Other Available Frequencies 150, 178, 200, 215 or 230 Lines/Inch, Depending on Model
Grid Geometry Focused or Parallel
Focal Distance Selected According to X-Ray Source-to-Image Distance
Example Focused Range 40–72 Inches, on Certain Models
Grid Orientation Portrait or Landscape
Outer Cover Material Aluminium or Carbon Fibre
Frame Protective Frame, Where Fitted
Image Receptor Compatibility Film-Screen, CR or DR
Mounting Cassette-Mounted, Detector-Mounted or Stationary Holder
Electrical Requirement None